Dummy Socket Eve Single Plus
Only for professional use by qualified personnel and professionals. For sale and delivery of Spare Part kits, the Alfen general terms and conditions of sale (the ‘General Terms’) and the Alfen Carry-in Warranty (the ‘”Warranty”) applies, which can be downloaded here: Terms & Conditions repair and/or maintenance of the Alfen Product(s) by an unauthorized party may result in loss of warranty.
SPK Dummy Socket Eve Single Plus 803874120
Contents of the kit
| Part number | Description | Quantity in the kit |
| 803993119-ICU | Dummy Socket Alfen Black | 1 |
| 079958041-ICU | Flangenut M4 | 3 |
| 803866396-ICU | Socket Seal Eve Single | 1 |
Step-by-step summarized instruction for "SPK Dummy Socket Eve Single Plus"
Open the front housing housing by removing the 6x Torx 20 screws
Lift the “Subframe” after removing the 3x Torx 20 screws
Separate the “Dummy Socket” from the “Subframe” by removing the 3x M4 Flangenuts
Mind the Socket Seal that is between the “Dummy Socket” and “Subframe”, save for reassembly
Isolate the old (defective) “Dummy socket” and grab the replacement “Dummy Socket”
Assemble the replacement “Dummy socket” on the “Subframe” and fix with the
3x M4 flangenuts (torque: 1Nm)
Mind that the Socket Seal is placed between the “Dummy Socket” and “Subframe” first
Place the “Subframe” back in the charger and fix with the 3x Torx 20 screws (torque: 1Nm)
Close the front housing and fix with the 6x Torx 20 screws (torque: 1Nm)