T2 Socket Eve Single Plus
Only for professional use by qualified personnel and professionals. For sale and delivery of Spare Part kits, the Alfen general terms and conditions of sale (the ‘General Terms’) and the Alfen Carry-in Warranty (the ‘”Warranty”) applies, which can be downloaded here: Terms & Conditions repair and/or maintenance of the Alfen Product(s) by an unauthorized party may result in loss of warranty.
SPK T2 Socket Eve Single Plus 803874118
EU variant only! This instruction is not applicable for the DE and FR products.
Contents of the kit
| Part number | Description | Quantity in the kit |
| 803993430-ICU | T2 Socket 3PH Single Plus EU | 1 |
| 079958041-ICU | Flangenut M4 | 3 |
| 803866396-ICU | Socket seal Eve Single Plus | 1 |
| 203130251-ICU | Spare Part Kit instructions | 1 |
Step-by-step summarized instruction for "SPK T2 socket Eve Single Plus"
Open the front housing housing by removing the 6x Torx 20 screws
Unplug the Hybrid Connector from the Socket to the SB100
Press both ledges to unlock while pulling the connector up
Lift the “Subframe” after removing the 3x Torx 20 screws
Separate the “T2 Socket” from the “Subframe” by removing the 3x M4 Flangenuts
Unplug the connector from the “Actuator”
Press the bottom ledge to release
Separate the Actuator from the “T2 Socket” by opening the 1x Philips 2 screw
Isolate the old (defective) “T2 socket” and grab the replacement “T2 Socket”
Assemble the Actuator on the replacement “T2 Socket” with the 1x Philips 2 Screw (1Nm or less)
Plug the connector in the Actuator
The bottom ledge should be locked
Assemble the replacement “T2 socket” on the “Subframe” and fix with the 3x M4 flangenuts (torque: 1Nm)
Place the “Subframe” back in the charger and fix with the 3x Torx 20 screws (torque: 1Nm)
Route the cable from the socket around the outside of the “Subframe” and plug the Hybrid Connector in the SB100
Ensure the connector is correctly placed, both ledges should be locked
Close the front housing and fix with the 6x Torx 20 screws (torque: 1Nm)