What does Error code 213 mean?

This article explains error code 213

Error213Errorcode
Applicable platform:
This error code can be found on chargers using the below platform(s):
  • AHP (Alfen Hardware Platform)
  • NG (Next Generation)
Error code 2xx | Error In Installation
Error codes starting with '2' indicate that the most likely cause for the problem is related to the Installation of the charger.
 

Error code:
213
 

Error message on display:

Not displayed
 

Possible Cause:
No connection / connection lost to TIC smart energy Meter

Possible solutions:
- Contact the service department of your charge point supplier.
- Check TIC smart energy Meter connection.

OCPP Statusnotification:
Info field: TIC lost, in safe mode max 6A. Check TIC connection
OCPP 1.5: OtherError
OCPP 1.6/2.0.1: OtherError

Suggestions:

  • During configuration, check that the ‘Phase Rotation’ setting matches the physical installation.
    For example, on a 1-phase installation, adjust the setting to ‘L1’.
    Example in ACE Service Installer:


    In Eve Control, the setting is referred to as ‘Phase-Connected’