KA-01751

AHP-Firmware version 2.8.0

This page provides information on firmware version 2.8.0 for the AHP-platform

AHPAlfen Hardware PlatformUpdate
Version:
2.8.0
Release date:
18-11-2026
Expiration date:
09-09-2027
 
Platform:

AHP (Alfen Hardware Platform):

  • Eve Single Plus

  • Eve Double Plus

  • Twin 4 V2G

  • Twin 5

  • Twin 5 Plus

  • Eve Public Flex

  • Eve Home

The firmware file has the extension *.tfw

Introduction:
Firmware release 2.8.0 incorporates several general improvements, stability improvements, bug fixes and features. The main new features are:
  • Support for Wireless commissioning

  • Support for Wireless LAN

  • Support for Eve Connect

  • Support for SPD health monitoring

WiFi connectivity
Wireless LAN
Support for wirelessly connecting the charging station to a local area network (LAN) using WiFi is introduced in this release. It provides flexibility to facilitate access to Eve Connect for installations where
ethernet cabling is impractical. The wireless LAN connection can be configured using the ACE Service Installer or an upcoming release of Eve Install as part of the commissioning process. Active Load
Balancing using a Modbus TCP/IP energy meter and connection to a Modbus TCP/IP Energy Management System (EMS) over wireless LAN. Smart Charging Network using a wireless LAN
connection is not supported. We generally recommend using a physical connection for Active Load Balancing. Note that only security profiles WPA2 and WPA3 are supported over 802.11 b/g/n on 2.4 GHz.


Wireless commissioning
This release introduces a direct wireless connection between a charging station and a mobile device for commissioning the charging station using an upcoming release of Eve Install. This will simplify the
commissioning process for an installer, whereas previously either a temporary physical connection to the charging station or access to the local area network was required. The charging station now creates a
wireless Access Point (AP), where Eve Install can connect to by scanning the provided password QR code during the commissioning process. The Access Point is activated after a power cycle and will be
deactivated after 15 minutes of inactivity. It is not possible to set up multiple charging stations from a 
single wireless connection, hence it is advised to use a wired connection to set up a charging plaza with a
Smart Charging Network.

New functionality

  • Facilitating charging schedules and charging current limits to be configured via Eve Connect for Eve Single Plus. Support for Eve Single Plus requires Eve Connect version 1.6.0 (or higher).

  • Added support for status monitoring of an internal Surge Protection Device (SPD) on Eve Double Plus and Twin 5 Plus. This can be configured to either Permissive or Strict to notify or block charging when an error is detected.

  • Implemented support for two simultaneous TCP/IP clients when using an Energy Management System (EMS) over Modbus TCP/IP. This allows the control of separate sockets of a double socket charging station with individual TCP/IP client.

  • Added support for HomeWizard P1 and Telnet P1 for Active Load Balancing and solar charging. Currently this can only be configured with the ACE Service Installer.

  • Introduced new light and dark user interface themes, including automatic switching based on sunrise and sunset. Additionally, support for separate customer logos in light and dark themes is added. It is currently only possible to set a theme using OCPP key DisplayColorTheme as described in the back-office configuration key list of this release.


Bug fixes

  • Fixed an issue where the charging station would not switch between single phase and three phase charging when this is requested via an OCPP charging profile.

  • Resolved an issue where resetting the owner password could result in login failures.

  • Fixed occasional false internal voltage errors during startup.

  • Fixed an issue where the buzzer would give a double rejected buzzer sound on double socket charging stations.

  • Fixed an issue where a RemoteStopTransaction with an outdated transaction ID would either stop charging or result in incorrect meter values to be reported. The charging station now ignores invalid RemoteStopTransaction commands.

  • Fixed an issue where valid OCPP1.6J RemoteStartTransaction requests sent after an invalid request were rejected.

  • Fixed an issue with the Control Pilot duty cycle during ISO15118 communication causing an error with modern EVs.

  • Fixed an issue where the high level communication with specific electric vehicles could cause a fixed cable charging station to get stuck on a waiting for power state or fail to detect the vehicle.

  • Fixed an issue where vehicles that only support DC charging over ISO15118 would go into a Suspended state.

  • Fixed an issue where charging stations going into the Suspended state would cause inconsistencies in the user interface.

  • Fixed an issue where the LED of the modem would interfere with the sensor used for tamper detection. The modem LED is now disabled.

Improvements

  • Added hardware support for Eve Home

  • Improved protection of passwords and security-sensitive information in OCPP communication.

  • Added additional security hardening of the REST interface following external security assessments.

  • Enhanced modem initialization and diagnostics, reducing unnecessary modem restarts and improving troubleshooting information.

  • Removed the AutoCharge blacklist handling to improve automated authentication behavior.

  • Improved handling of low supply voltage events during startup to avoid unnecessary Error 104 messages.

  • Improved communication with DSMR 4.2, DSMR 5 and TIC Standard smart meters

SCN cross platform compatibility

Our Smart Charging Network (SCN) functionality is implemented as a shared library between our NG9 platform and AHP platform to enable cross compatible SCNs.

SCN versions are not backwards compatible; each charging station in the SCN needs to run firmware which contains the same SCN version.

Charging stations running AHP firmware 2.7.0 can only be combined in a single Smart Charging Network with charging stations running NG9xx firmware 7.4.x.

The ACE Service Installer will provide a warning if charging stations with different SCN library versions are used in one SCN.

Please refer to the SCN compatibility matrix below to firmware version compatibility. For the most recent status on this topic, please refer to our
For the most recent status on this topic, please refer to the dedicated page on our Knowledge Base.

Firmware update instructions

Please be aware that due to cybersecurity requirements, it is not possible to downgrade AHP firmware.
An expiration date applies to the firmware file of the final release. 
After the expiration date, the charging station will reject to update with this release and will require a newer release to be used for an update.
The expiration date for this release is the 9th of September 2027.

Known limitations

  • Changing the phase rotation of the charging station requires a reboot to be effective.

  • Adding a charging station to a Smart Charging Network requires a reboot to be effective.

  • An error associated with a trip of the Residual Current Device on an Eve Double Plus DE will get incorrectly cleared when the transaction is ended. This can be resolved by performing a power cycle.

  • In the case that the back-office does not support the signing of V2G certificates, the charger will send an error to the back-office that the certificate signing is rejected. 
    This can be resolved by disabling the V2G certificate request using ISO15118Ctrlr/V2GCertificateInstallationEnabled.

  • Configuring a Modbus TCP/IP based energy meter requires a reboot of the charging station to be effective.

  • It is currently not possible to configure a specific dark themed logo using ACE Service Installer or Eve Install.
     

Notes
For the use of a three-phase charging station on a single-phase installation, the maximum allowed phases needs to be set to 1.
If Active Load Balancing is used, the phase mapping needs to be configured to L1 and the phase rotation to Single Phase.